http://WWW.SUMEETTRANSFORMER.COM
http://WWW.SUMEETTRANSFORMER.COM

Checking delivery availability...

background-sm
Search
3

Updates found with 'examine'

Page  1 1

Updates found with 'examine'

ANNUAL MAINTENANCE CONTRACT (AMC) IS IMPORTANT TO PROTECT YOUR TRANSFORMERWe are the best transformer service and maintenance services providers in Vadodara, Gujarat, India Our Annual Maintenance Contracts for the most part incorporates substitution of flawed parts/supplanting of entire units alongside in the vicinity bolster. Here and there, Annual Maintenance Contracts would require the client to hand over faulty units/send them over to the manufacturing plant which would be come back to them after the blame is amended At the point when to agree to accept AMC? We accentuate on agreeing to accept AMC contracts before the guarantee/past AMC contract terminates to keep away from unanticipated expenses out of guarantee. We attempt a Preventive Maintenance check for every one of the types of gear secured under the AMC, in any event once in a half year. The cost of the AMC contract every year for transformers and AVRs is 8% to 10% of the first cost of the gear. This can likewise shift in light of kind of the hardware. There is one more kind of administration that we offer. Here, the client is charged an administration charge that covers the overhauling/repairs, and so on location for a year. Be that as it may, if there are any damaged segments, the same must be supplanted by the client at their own particular cost.Essential Maintenance Scope (A) Visual and Mechanical Inspection: Examine physical conditions for oil spillages, oil level, repair of spillage assuming any. Examination for electrical association snugness, establishing Etc. Examination for Cracks and Dust in Bushing, Gasketted Joints, Bushing Replacement, Replacement of Gasket Electrical Inspection for transformer stacking, coherence, examination for snugness of earth association in pits. Assessment for legitimate task of radiator valves, deplete valves Etc. Completely wipe down, vacuum, and tidy transformer. Check for air sections are clear. Check for shade of dynamic operator in Silicagel Breather. Investigation of Insulating oil for electrical quality, oil filtration and oil substitution is required. Painting of transformer if required. Checking and Testing of Protective Gear like WTI, OTI, Buchholz Relay, MOLG Etc. (B) Electrical Tests Performed on transformers: Protection testing through catapulted associations Protection tests, twisting to winding, and each twisting to ground.. Turns-proportion tests at all tap positions Check for BDV of Insulating Oil. Disintegrated Gas Analysis of transformer oil. Aside from above we are likewise having the choice for establishment of ONLINE CONDITION MONITORING SYSTEM on transformer through which we can do the ongoing checking of transformer for any early blames and furthermore analyze the transformer for various parameters, some of them are as underneath: H2 PPM Level Surrounding, Oil and Winding Temperature Voltage and Current in every one of the three stages. Dynamic/Reactive clear vitality and power Most extreme request/Demand anticipating Time bound and stamped information for KVAH/KWH/KVARWe are the best transformer service and maintenance services providers in Vadodara, Gujarat, India.We are the best transformer service and maintenance services providers in Surat, Gujarat, India We are the best transformer service and maintenance services providers in Ahmedabad, Gujarat, India
Send Enquiry
Read More
Transformer Maintenance Schedule on Yearly Basis Services provider in Bharuch and Ankleshwar.The auto, remote, manual capacity of cooling framework that implies, oil pumps, air fans, and different things occupied with cooling arrangement of transformer, alongside their control circuit to be checked in the interim of one year. Stuck in an unfortunate situation, examine control circuit and physical state of pumps and fans. Every one of the bushings of the transformer to be cleaned by delicate cotton fabrics yearly. Amid cleaning the bushing ought to be checked for breaking. Oil state of OLTC to be analyzed in consistently. For that, oil test to be taken from deplete valve of divertor tank, and this gathered oil test to be tried for dielectric quality (BDV) and dampness (PPM). On the off chance that BDV is low and PPM for dampness is discovered high contrasted with suggested esteems, the oil inside the OLTC to be supplanted or separated. Mechanical examination of Buchholz transfers to be completed on yearly premise. All marshaling boxes to be cleaned from inside in any event once in a year. All enlightenment, space radiators, to be checked whether they are working appropriately or not. If not, required support move to be made. All the terminal associations of control and hand-off wiring to be checked a fix in any event once in a year. All the transfers, alerts and control switches alongside their circuit, in R& C board (Relay and Control Panel) and RTCC (Remote Tap Changer Control Panel) to be cleaned by fitting cleaning operator. The pockets for OTI, WTI (Oil Temperature Indicator and Winding Temperature Indicator) on the transformer top cover to be checked and if expected oil to be recharged. The best possible capacity of Pressure Release Device and Buchholz transfer must be checked yearly. For that, trip contacts and alert contacts of the said gadgets are shorted by a little bit of wire, and watch whether the concerned transfers in remote board are appropriately working or not. Protection and polarization list of transformer must be checked with battery worked megger of 5 KV extend. Resistive estimation of earth association and rizer must be estimated every year with clip on earth protection meter. DGA or Dissolve Gas Analysis of transformer Oil ought to be performed, every year for 132 KV transformer, once in 2 years for the transformer beneath 132 KV transformer and in 2 years interim for the transformer over 132 KV transformer. The Action to be taken once in 2 years : The alignment of OTI and WTI must be conveyed once in two years. Tan and delta; estimation of bushings of transformer likewise to be done once in two years. Transformer Maintenance Schedule on Yearly Basis Services provider in BharchTransformer Maintenance Schedule on Yearly Basis Services provider in AnkleshwarTransformer Maintenance Schedule on Yearly Basis Services provider in Vapi.Transformer Maintenance Schedule on Yearly Basis Services provider in Daman and Diu.Transformer Maintenance Schedule on Yearly Basis Services provider in Valsad.Transformer Maintenance Schedule on Yearly Basis Services provider in Vyara.Transformer Maintenance Schedule on Yearly Basis Services provider in Tapi.
Send Enquiry
Read More
Page 1 0.3