Updates found with 'high tension'

Transformer Overhauling Services and Maintenance with yearly AMC Services in Vadodara, Gujarat, India.We provide better service for your transformer protection.There are various types of transformers, for example, two winding or three winding electrical power transformers, auto transformer, controlling transformers, earthing transformers, rectifier transformers and so on. Distinctive transformers request diverse plans of transformer security relying on their significance, winding associations, earthing techniques and method of operation and so on. It is basic practice to give Buchholz hand-off assurance to every one of the 0.5 MVA or more transformers. While for all little size dispersion transformers, just high voltage wires are utilized as primary defensive gadget. For all bigger appraised and imperative circulation transformers, over current security alongside confined earth blame insurance is connected. Differential security ought to be given in the transformers evaluated over 5 MVA.Transformer Overhauling Services and Maintenance with yearly AMC Services in Surat, Gujarat, India.Transformer Overhauling Services and Maintenance with yearly AMC Services in Ahmedabad, Gujarat, India.Transformer Overhauling Services and Maintenance with yearly AMC Services in all over in gujarat, india For more info visit us at http://sumeettransformer.com/Transformer-Overhauling-Services-and-Maintenance-with-yearly-AMC-Services-in-Vadodara-Gujarat-India-We-provide-better-se/b24
Send Enquiry
Read More
Transformer Overhauling Service in Vadodara, Gujarat, IndiaThe essential significance of Overhauling is to inspect or go over deliberately for required repairs. During the time spent Overhauling Engineers open the entire Transformer to do the needful cleaning, repair and substitution, in short the procedure incorporates general investigation including lifting of center and curls.Transformer Overhauling, Leakage Arresting & Elect. TestingDismantling of Transformer & Draining of OilLifting, Cleaning and Tightening of Core & Coil Assemblytransformer maintenanceGasket ReplacementNitrogen PurgingIR Value Improvement by High Vacuum Oil CirculationWinding Insulation Paper Measurement of DP for RLAInitial & Pre-Commissioning TestingWinding ResistanceTurn Ratio TestNo Load/ Load LossesTan Delta & Capacitance Tests on Bushing & windingDuration of Work:After every 5 yrs for 1000 to 3000 KVAAfter every 7-10 yrs for 3000 and above KVABenefits:Increase IR ValueIncreases 10 times age of your TransformerReduce maintenance expensesImprove Transformer reliabilityReduce unnecessary repair/replacement costsWe also provide industrial lighting Service in all over Gujarat.Transformer Overhauling, Leakage Arresting & Electrical Testing Service in Vadodara, Gujarat, IndiaTransformer Overhauling, Leakage Arresting & Electrical Testing Service in Ahmedabad, Gujarat, IndiaTransformer Overhauling, Leakage Arresting & Electrical Testing Service in Surat, Gujarat, India
Send Enquiry
Read More
Transformer Oil Testing and Analysis Service Providers in Vadodara, Gujarat, IndiaNormal Oil investigation is helpful in checking the state of motors, turbines and other oil greased up gear. This same thing is connected on Transformer oil, used to protect numerous transformers and other electrical appropriation hardware. The examination of protecting oils gives data about the oil, yet in addition empowers the recognition of other conceivable issue, including contact arcing, maturing protecting paper and other dormant blames and is as crucial piece of cost-effective electrical support program.There are 8 Tests as per IS: 1866Electric Strength (BDV)Water Content (PPM)Di-electric Dissipation factor (Tan Delta)Specific Resistance (Resistivity)Neutralization Value (Acidity)Sediment (Sludge)Flash PointInterfacial TensionTransformer Oil Testing as per IS: 10593Dissolved Gas Analysis (07 Gasses)Methane, Ethylene, Ethane, Acetylene, Hydrogen, Carbon Mono Oxide & Carbon DioxideDissolved Gas Analysis (09 Gases)Methane, Ethylene, Ethane, Acetylene, Hydrogen, Carbon Mono Oxide, Carbon Dioxide, Propane & Propylene.Transformer Oil Testing as per IEC: 1198Furan Analysis: –Residual Life Assessment (5 Compounds)5-Hydroxy Methyl– 2 Furfural2 – Furfural2 – Acetyl Furan2 – Furfuryl Alcohal5 – Methyl – 2 – FurfuralTransformer Oil Testing and Analysis Service Providers in Vadodara, Gujarat, IndiaTransformer Oil Testing and Analysis Service Providers in Ahmedabad, Gujarat, IndiaTransformer Oil Testing and Analysis Service Providers in Surat, Gujarat, India
Send Enquiry
Read More
Page 1 1